Saunier Duval THEMA F 23 E Installation Instruction

Page of 28
27
FAULT FINDING
NO HOT WATER
Replace main pcb
Refer to chart n
°
2
Check mains water
supply, water filter
Is there at least 3 litres/min
water flow at tap ?
Remove leads from boiler
thermistor. Check its resistance
in accordance with thermistor
value table. Is thermistor ok ?
Check operation of water valve
diaphragm. Does reversing
valve mechanism move when
hot tap is opened ?
Replace
diaphragm
Replace thermistor
Open hot tap fully.
Does burner fire ?
YES
NO
NO
YES
YES
NO
With selector switch/thermostat
in
position and turner to maxi-
mum. Does burner fire for CH ?
Is there continuity across DHW
microswitch and PCB
 connections cn 6.4 and cn 6.9 ?
YES
Replace dhw
microswitch
Is there 240 v at pump ?
YES
Is there 240 v at
terminal cn2 of PCB ?
Is there 240 v at fan ?
NO
YES
CHART 2
NO
NO
NO
CHART 3
PUMP NOT RUNNING
FAN NOT RUNNING
Replace main PCB
YES
CHART 4
NO
NO
Is pump jammed ?
Replace
pump motor
NO
Free pump
Replace main PCB
Is fan jammed ?
Replace fan
NO
SPARE PARTS
When ordering spare parts, quote the part number and description, stating the appliance model number
and serial number from the data badge.
Short parts list
No.
Description
Part No.
1
Fan
57059
2
Pump
51236
3
Spark generator
51110
4
Air pressure switch
51692
5
Main PCB (SB models)
57267
6
Main PCB (THEMA F 23 E)
57265
No.
Description
Part No.
7
Control PCB (all models)
57277
8
Water valve diaphragm kit
52519
9
Microswitch assembly (THEMA F 23 E)51590
10
Temperature/pressure gauge
57278
11
Boiler Thermistor
57060
12
Overheat thermostat
51199
Temperature  (
°
C)
0
5
10
15
20
25
30
35
40
45
50
nominal resistance (
Ω
) for NTC
32565 25345 19875 15700 12500 10000
8060
6535
5330
4370
3605
Temperature  (
°
C)
55
60
65
70
75
80
85
90
95
100
nominal resistance (
Ω
) for NTC
2989
2490
2085
1755
1480
1260
1070
920
785
680
Termistor Values
(except SB models)