Appendix G - PTZ Parallel Measurement Laser Calibration
• Setup PTZ system. Refer to “
System Setup” on page 12.
• Point the camera with the laser attachment tilted away from the PTZ body to allow access to
the laser housing.
the laser housing.
• Remove the front cap off each laser (fig. 70).
• Turn the lasers on via the camera menu (fig. 71).
• Using a 0.050 in. (1.3 mm) hex key, turn the screw on the side of the laser housing to steer
the laser dot in the horizontal plane.
the laser dot in the horizontal plane.
• Turn the screw on the top of the laser housing to steer the laser dot in the vertical plane.
• Point the camera at a target 10 m (30 ft.) away, this should be a flat surface, perpendicular
to the camera. Use a scale or a grid to determine the distance between the laser dots, the
dots need to be 2 in. (50 mm) apart horizontally (fig. 74).
to the camera. Use a scale or a grid to determine the distance between the laser dots, the
dots need to be 2 in. (50 mm) apart horizontally (fig. 74).
Figure 70
Figure 7
Figure 72
Figure 73
Figure 74