GE Ca-Zoom PTZ 70 Operating Guide

Page of 105
Everest Ca-Zoom
®
 
6.2
Appendix G - PTZ Parallel Measurement Laser Calibration
• Setup PTZ system.  Refer to “
System Setup” on page 12. 
• Point the camera with the laser attachment tilted away from the PTZ body to allow access to       
   the laser housing.
• Remove the front cap off each laser (fig. 70).
• Turn the lasers on via the camera menu (fig. 71).
• Using a 0.050 in. (1.3 mm) hex key, turn the screw on the side of the laser housing to steer        
   the laser dot in the horizontal plane.
• Turn the screw on the top of the laser housing to steer the laser dot in the vertical plane.
• Point the camera at a target 10 m (30 ft.) away, this should be a flat surface, perpendicular
   to the camera.  Use a scale or a grid to determine the distance between the laser dots, the    
   dots need to be 2 in. (50 mm) apart horizontally (fig. 74).
Figure 70
Figure 7
Figure 72
Figure 73
Figure 74
94