Robertshaw 9420 User Manual

Page of 12
DIGITAL 
NON-PROGRAMMABLE 
THERMOSTAT
9420
HEAT PUMP
H
NeW
2 Heat / 2 Cool 
User's Manual
Quick Start
Installation
Application
The Robertshaw 9420 is a multi-stage thermostat designed to control 
24 VAC heat pump systems.
Features
• Summer and winter setpoints
• Large back lit display
• Adjustable 1
st
stage temperature differential: 0.5°F to 3.0°F 
(0.5°C to 1.5°C)
• Adjustable 2
nd
stage temperature differential: 1°F to 6°F 
(0.5°C to 3.0°C)
• Adjustable 2
nd
stage delay (10-40 min.)
• Compressor short cycle protection
• Accuracy within ±1°
• Zone system compatible as a master thermostat
• Permanent memory retention
• Fahrenheit/Celsius display option
• Adjustable from 45°F  to 90°F (7°C - 32°C)
• Quick wire terminal block
• Automatic heating shutdown if temperature exceeds 94°F (34°C)
1
110-1044B