Pelco BB14 Series C454M-C User Manual
12
Pelco Manual C454M-C (1/98)
3.2 WIRING INSTRUCTIONS
How your back box will be wired depends on the type of unit you have:
Units with an on-board receiver/driver
Units without an on-board receiver/driver (hard-wire applications)
Units without an on-board receiver/driver (hard-wire applications)
Hardwire refers to installations using a remote receiver/driver or a true hardwire
controller.
controller.
Proceed to either Section 3.2.1, On-Board Receiver/Driver, or Section 3.2.2,
Hardwire or Remote Receiver/Driver.
Hardwire or Remote Receiver/Driver.
3.2.1 On-Board Receiver/Driver
On models for suspended ceilings or hard ceilings, a plate is provided on the top of
the back box with 1/2" and 3/4" conduit knockouts.
the back box with 1/2" and 3/4" conduit knockouts.
1.
Bring the wiring to the back box.
Video - Refer to Table A for the type of video coaxial cable to use.
Power - If the input power to the dome is 24 VAC, refer to Table B to determine
the size of wire to use. For outdoor units, make sure the wiring can supply
power for the heaters and fan as well as the receiver/driver. Refer to Section
5.0, SPECIFICATIONS, for power requirements.
the size of wire to use. For outdoor units, make sure the wiring can supply
power for the heaters and fan as well as the receiver/driver. Refer to Section
5.0, SPECIFICATIONS, for power requirements.
Control - If you are using a Coaxitron
®
controller, the control signals to operate
the dome drive will be transmitted over the video coax.
If you are not using a Coaxitron
®
controller, bring wires to the back box for two
(2) RS-485 control lines (RX+ and RX-).
Refer to Figure 3, 4, or 5 for the following steps.
2.
Install the coaxial cable to the BNC connector.
3.
Install power to the 10-position terminal block. Make sure the power switch on
the side of the back box is off.
the side of the back box is off.
4.
If you are not using Coaxitron
®
control, connect the control wiring to RXD+
and RXD-.
From controller
To 4-wire terminal inside back box
TXD+
RXD+
TXD-
RXD-
Proceed to Section 3.3, DOME DRIVE INSTALLATION.