Peerless Lighting Lighting Work Light ACC570 User Manual

Page of 4
ISSUED: 11-14-07   SHEET #: 054-9054-5
Visit the Peerless Web Site at www.peerlessmounts.com
For customer care call 1-800-729-0307 or 708-865-8870.
3 of 4
A
B
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (A) to the joist center
using two #14 x 2.5" wood screws (B) as shown. Tighten wood screws (B) using 3/8" (10 mm) socket wrench so
ceiling plate (A) is firmly attached.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the wood joist or wood beam. The use of an
"edge to edge" stud finder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood joist or
wood beam ceilings. Installers are responsible to provide hardware for other types of mounting situations.
WARNING
3
Installation to Wood Joist Finished Ceilings, Exposed Wood Joists,
or Wood Beam Ceilings