Paradise 205486 REV F User Manual

Page of 124
Operations Manual, HPA2, Compact Outdoor SSPA 
205486 REV F 
117 
Baud Select Lines on J4, Monitor & Control Connector 
 
Pins j and e of M&C connector J4 allow the user to have  some  control  over  the  serial          
interface, bypassing EEPROM settings for Protocol, Baud Rate or Network Address. This  
feature becomes important if the user accidentally selects the wrong protocol or baud rate of 
the SSPA and wants to revert the unit to a known state. 
 
These pins have internal pull-ups and if left disconnected will remain in logic high state. The 
reverting function of the SSPA is active only on initial power-up. Any alterations to the pins’ 
state after start-up will allow the SSPA to use internal EEPROM settings to select the baud 
rate and protocol. These pins also are used automatic addressing. This option will work with   
I/O board firmware levels of 3.50 or later. Do not attempt to activate this option on units with 
earlier firmware versions! 
 
To revert an SSPA to a known interface state, complete the following steps: 
1.  Turn off the SSPA; 
2.  Establish wire jumpers to the M&C connector J4 according to the desired protocol 
selection (See Table C-1); 
3.  Turn on SSPA and remove the jumpers; 
4.  Connect to SSPA over serial protocol and select the desired settings for  protocol 
and baud rate. Settings will take effect after next SSPA power-up. 
To turn on automatic addressing: 
1.  Connect to the SSPA over serial interface; 
2.  Set the SSPA unique network address to 170 (Hex 0xAA) 
3.  Cycle the unit’s power. The unit will start with default baud rate of 9600 and      
Standard String Protocol selection. Pins j and e now will determine the SSPA 
unique address (See Table C-2). 
Jumper 1 
Jumper 2 
Selected Protocol 
Selected Baud Rate 
j-d 
e-V 
Standard String Protocol (see Section 10) 
9600 
none 
e-V 
Standard String Protocol (see Section 10) 
38400 
j-d 
none 
Binary Protocol compatible with CO SSPA with 
serial number 100,001 - 199,999 
38400 
none 
none 
Settings last saved to EEPROM 
EEPROM setting 
Table C-1: Baud Rate and Protocol Reverting Options 
Table C-2: Unique Network Address Hardware Select † 
Jumper 1 
Jumper 2 
SSPA unique address 
j-d 
e-V 
j-d 
none 
none 
e-V 
none 
none 
† SSPA address in EEPROM must be selected to 0xAA in order to activate  this option. 