Paradise 205486 REV F User Manual

Page of 124
26 
 205486 REV F 
Operations Manual, HPA2, Compact Outdoor SSPA 
Table 3-1: Monitor & Control Connector, J4 
 
Signal 
Type 
Function 
Pin 
Notes 
Mute Input 
Closure to Ground 
Disables DC Power to SSPA 
Unit Powers up Muted, This line must 
be pulled to ground (V or d) to enable 
amplifier 
Auxiliary Input 
Closure to Ground 
Auxiliary Fault Input 
 
Summary Alarm 
Form C Relay 
Closed on Fault 
Common 
Open on Fault 


L-a : normally open 
 
a-b : normally closed 
Auxiliary Alarm 
Form C Relay 
Closed on Fault 
Common 
Open on Fault 
N-Z : normally open 
 
Z-M: normally closed 
 
Open Collector 
High on Fault 
Reserved 
Auxiliary Alarm 
Open Collector 
High on Fault 
Requires external pull-up 
Voltage Alarm 
Open Collector 
High on Fault 
Requires external pull-up 
Current Alarm 
Open Collector 
High on Fault 
Requires external pull-up 
Temperature Alarm 
Open Collector 
High on Fault 
Requires external pull-up 
RF Power Detector 
Analog Output 
Relative Indication of RF Output 
Power 
+4.0 vdc at Psat 
Gain Adjust Input 
Analog Input 
Adjusts Amplifier Gain over 20dB 
range 
2.5 vdc = Max Gain 75dB 
0.5 vdc = Min Gain 55dB 
Block Up Converter 
Alarm 
Open Collector 
High on Fault 
Requires external pull-up 
RS232 / RS485  
Select 
Closure to Ground 
Selects Serial Communication 
Default is RS 485; pull to ground (V) 
to enable RS 232 
RS 485 TX-    or 
RS232 OUT 
Serial TX Output 
Serial Link Data Port 
 
RS 485 RX-   or 
RS232 IN 
Serial RX Input 
Serial Link Data Port 
9600 default Baud Rate 
RS 485 TX+ 
Serial TX Output 
Serial Link Data Port 
  
RS 485 RX+ 
Serial RX Input 
Serial Link Data Port 
 
GND 
Signal Ground 
Common Signal Return 
V, d 
 
Baud Select 0 
Closure to Gnd 
Select Baud Rate & Protocol 
Refer to  Appendix C 
Baud Select 1 
Closure to Gnd 
Select Baud Rate & Protocol 
Refer to  Appendix C 
PGM Switch 
 
Flash Firmware Port 
Reserved for Programming 
PGM-Sout 
 
Flash Firmware Port 
Reserved for Programming 
PGM-Sin 
 
Flash Firmware Port 
Reserved for Programming 
PGM +5V 
 
Flash Firmware Port 
Reserved for Programming 
PGM Enable 
 
Flash Firmware Port 
Reserved for Programming 
Spare Fault 
Open Collector 
High on Fault 
Requires external pull-up 
PGM CLK 
 
Flash Firmware Port 
Reserved for Programming