Paradise 205486 REV F User Manual

Page of 124
50 
 205486 REV F 
Operations Manual, HPA2, Compact Outdoor SSPA 
Each amplifier can be configured for redundancy by the Paradise Datacom Universal M&C 
software that ships along with each unit. Using the Quick-Start cable, connect each amplifier 
to the PC and run the M&C program.  Select the “Settings” tab from the main form.  The 
“Settings” window will appear as shown in Figure 7-8. 
 
1. System Mode: Each SSPA’s System Mode must be set to “1:1 Redundant Mode” 
 
2. Choose a Hierarchical Address for each amplifier.  HPA 1 means this SSPA will use 
the RF switch position 1 as its On Line state position.  HPA 2 will then use RF 
switch position 2.   
 
3. Redundancy Startup State: The amplifier which is desired to be on line should be set 
“On Line”.  The other amplifier should be set as “Standby”. 
 
All settings are valid as soon as the operator sets them on the SSPA Settings window. The 
SSPA’s redundant operation can be verified by monitoring the RF Switch Fault indicator as 
shown in Figure 7-15.   
Figure 7-8:  M&C Program “SSPA Settings” window