Paradise 205486 REV F User Manual

Page of 124
54 
 205486 REV F 
Operations Manual, HPA2, Compact Outdoor SSPA 
Once reliable communication has been established between each amplifier and the computer, 
the Redundancy Control Panel can be displayed.  From the M&C program’s main window, 
choose “Action”   “Internal Redundant System”   “1:1 Compact Outdoor SSPA System”. 
See Figure 7-12.  
The Redundant Control Panel window will then be displayed as in Figure 7-13. Note that once 
the Redundant Control Panel is enabled, the Main Menu on the M&C program changes. 
The Control Panel must be configured by selecting “Set Redundancy System” and choosing 
an amplifier for SSPA 1 and SSPA 2.  Either amplifier may be designated as SSPA 1 or 
SSPA 2. Each amplifier is identified by its ID number. The ID number is a fixed number and 
cannot be changed.  It is a unique encoded value determined by the particular amplifier’s 
model number and serial number. If the ID number is forgotten,  refer to the System Watcher 
window. This window continuously displays which amplifier, by ID number, is connected to 
each specific COM port. After the Control Panel has been configured the display will change 
to the view shown in Figure 7-14. 
Figure 7-12:  Paradise Datacom Universal M&C, Add Unit Menu Tree 
Figure 7-13:  Add 1:1 Redundant System Window