Paradise 205486 REV F User Manual

Page of 124
68 
 205486 REV F 
Operations Manual, HPA2, Compact Outdoor SSPA 
Figure 8-2: 1:1 Fixed Phase Combined System with FPRC-1100 controller 
A technique has been developed which accomplishes phase combining and provides 
redundancy with two waveguide transfer switches. A block diagram of such a system is 
shown in Figure 8-2.  
 
This type of system is sometimes referred to as a “Fixed Phase” combined system to 
differentiate it from the Variable Phase Combiner (VPC) systems commonly used with 
TWTAs. In the 1:1 Fixed Phase Combined system, the waveguide switches allow the 
amplifier outputs to either be directed into the combiner or bypass the combiner and connect 
directly to the RF output. 
 
Paradise Datacom has developed a series of controllers that greatly enhances the   operation 
of the phase combined system. The FPRC-1100 Phase Combined System Controller is 
designed specifically to control 1 for 1 Fixed Phase Combined redundant amplifier systems. 
The FPRC-1200 Phase Combined System Controller allows remote control of 1 for 2 Fixed 
Phase Combined redundant amplifier systems. 
 
Each controller can be used in either manual or automatic mode to monitor the system 
amplifiers for faults and operate the transfer switches. The controller has a very user friendly 
interface that allows the operator to monitor the composite output power of the system and 
adjust the gain of the amplifiers in 0.1 dB increments over a 20 dB range. The controller 
adjusts each amplifier in the system and keeps the amplitude of each balanced for optimal