5. Loosen the connector before install the flat cable. 
     
 
6. Connect the flat cable between the Centronics parallel interface board and the main 
board. 
 
 
 
 
7. Connect the 5-pin cable between the Centronics parallel interface board and main board. 
 
8. Reassemble the parts in the reverse procedures.