Omega DPF500 Series User Manual

Page of 18
12
Chapter  7   Specifi cations
ENVIRONMENTAL:
OPERATING TEMPERATURE
   -4°F (-20°C) to  + 158°F (70°C)
  Extended Temp:  -22°F  (-30°C) to + 158°F (70°C)
HUMIDITY
  0 - 90% Noncondensing
MOUNTING STYLES:
1- Panel Mount -  
NEMA 4X Front
2- Wall Mount -  
NEMA 4X Enclosure
   
 (keypad mounted behind clear cover)
3- Explosion Proof - 
Class I, Division I, Groups B, C & D
   
Class II, Division I, Groups E, F & G
INPUTS:
MAGNETIC PICKUP INPUT
  Frequency Range: 0 to 3500 Hz 
  Trigger Sensitivity: 30 mV p-p (10 mV p-p on special order)
  Over Voltage Protected: ± 30 VDC
OPTO-ISOLATED DC PULSE INPUT
  High (logic 1): 4-30 VDC
  Low (logic 0): Less Than 1 VDC
  Minimum Current: .5 mA
  Hysteresis: 0.4 VDC
  Frequency Range: 0 to 5 kHz  
  Min. Pulse Width: 0.1 msec
CONTACT CLOSURE INPUT (contact closure to common)
  Internal Pullup Resistor: 100 KΩ to +3.6 VDC
  High (logic 1): Open or 4-30 VDC
  Low (logic 0): Less Than .5 VDC
  Internal Switch Debounce Filter: 0 to 40 Hz
NOTE:   Sustained contact closure will shorten 
   
battery life.
RESET INPUT (contact closure to common)
  Internal Pullup Resistor: 100 KΩ to +3.6 VDC
  High (logic 1): Open or 4-30 VDC
  Low (logic 0): Less Than .5 VDC
  Minimum On : 25 msec
NOTE:   Sustained contact closure will shorten 
   
battery life.
K-FACTOR
  Range: 0.001 to 99999999
  Decimal Point Locations: XXXX.XXXX to XXXXXXXX
20 POINT LINEARIZATION -LIN OPTION
  This  feature  allows  the  user  to  enter  20  different  frequencies 
with 20 different corresponding K-Factors to linearize non linear 
signals.
ANALOG OUTPUT -MA OPTION:
  Type: 4-20 mA follows rate display, Two wire hookup
  Accuracy: 0.025% Full Scale at 20° C
  Temperature Drift:  50 ppm/°C Typical
  Reverse Polarity Protected
  Update Rate: 8 times/second
NOTE: The DPF500 uses the 4-20 mA loop power as its primary 
power source when this option is used.  The battery is still 
required for standby battery operation.
DATA STORAGE:
  Setup Information: Stored in fl ash memory
  Totalizer:  Stored  in  battery  backed  RAM  but  can  be  saved  to 
fl ash memory by operator for recall after battery change out.
7.1 Specifi cations
Power:
BATTERY POWERED
  Supplied with 1 or 2 C size Lithium battery pack.
EXTERNAL POWER INPUT
  Voltage: 8.5 to 30 VDC
  Current: Less than 5 mA
  Supplied with 1 C size lithium battery
  Protection: Reverse Polarity Protection on DC Power Input
LOOP POWERED
  Voltage: 8.5 to 30 VDC
  Supplied with 1 or 2 C size lithium battery(ies)
  Protection: Reverse Polarity Protection on Current Loop
  Loop Burden: 8.5V maximum
BATTERY LIFE EXPECTANCY:
Expected Years of Operation for DPF500 of various powering op-
tions at equipment duty cycles
MODEL
RUN TIME
 
Idle 
2hrs/day 
8hrs/day  24hrs/day
-BAT*  
10 yrs 
10 yrs 
10 yrs 
9.1 yrs 
-BAT-LIN 
10 yrs 
10 yrs 
10 yrs 
8.4 yrs
Standard unit   10 yrs 
10 yrs 
10 yrs 
10 yrs
and -MA
(standby-operation)
Standard unit   Indefi nite operation when externally powered
and -MA
External or loop power
* -BAT option contains DPF5-BP battery pack
NOTE:  Battery shelf life is rated at 10 years by manufacturer
 
Life expectancy based on rated battery capacity at 20°C
 
The above table is shown with pulse output inactive. Use 
of pulse output shortens battery life.
 
Example: A pulse output of 0.06 sec. duration, once per 
second, would derate the battery life by 20%. 
 
DISPLAY:
Rate Display: (selectable decimal)
  5 Digits (99999), 0.35" High, Display updates once per second 
with battery power, 8X per second with DC or Loop power
  Rate Descriptors:  
/SEC, /MIN, /HR
  Min. Input Frequency: 0.01 Hz to 10 Hz (selectable delay of 0.1 
to 99.9 seconds)*
  Selectable Rate Display Damping
Totalizer Display:  (selectable decimal)
  8 Digits (99999999), 0.2" High
  Totalizer Descriptors:   GAL, LIT, FT3, M3,  "blank" 
    
Warning Displays: Low battery warning
PULSE OUTPUT:
  The pulse output advances with the least signifi cant digit of the 
totalizer or decimal multiples there of (see Pulse scale divider).
  Type: Isolated photomos relay
  Max. voltage (off state): 30 VDC
  Current (on state): 100mA
  Pulse Duration: Selectable 0.5, 0.25, 0.125, 0.0625 seconds
  Pulse Scale divider (Pulscale): User selectable, ÷1, ÷10, ÷100 
or OFF
  NOTE: Select OFF for max. battery life.
ACCURACY:
  0.01% Reading, ±1 count
  Temperature Drift: 50 ppm/°C Worst Case
*  A large delay setting and internal math operations may delay the update rate.
-BAT*  
10 yrs 
10 yrs 
10 yrs 
9.1 yrs