WARNING:  
ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE 
DANGEROUS.
 
 
GAS CONNECTION 
 
Check gas type.  Use only the type of gas indicated on the valve rating plate.  If the type of gas listed on 
the plate is not your type of gas supply, DO NOT INSTALL.  Contact your dealer for proper model. 
Always use an external regulator for all LP heaters to reduce the supply tank pressure to a maximum of 
13" W.C.   This is in addition to the regulator furnished with the heater. 
 
WARNING: 
CONNECTION DIRECTLY TO AN UNREGULATED LP TANK CAN  CAUSE 
AN  EXPLOSION. 
 
The normal gas connection is 3/8” N.P.T. made at the left side (facing the front of the appliance)  of the 
appliance. If a right side connection is desired, the connecting pipe may be led under the rear of the 
burner base to terminate at the right side for connection to the inlet of the valve. 
 
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas. Test for 
leaks using a solution of soap and water after completing the connection. DO NOT USE OPEN 
FLAME.
 
 
 
 
WARNING: 
Installation and repairs should be performed by a qualified service person.  The 
appliance should be inspected before use and at least annually by a professional service person. 
More frequent cleaning may be required due to excessive lint from carpeting, bedding material, 
etc. It is imperative that control compartments, burners and circulating air passageways of the 
appliance be kept clean. 