GAS PRESSURE CHECK 
Check the inlet pressure to the burner to insure that it is as shown in the table below. 
 
NOTE:  The pressure check point is located on the right side of the valve facing burner. 
 
The appliance and its appliance main gas valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of 1/2 
psi (3.5kPa). 
 
The appliance must be isolated from the gas supply piping system by closing its equipment 
shut-off valve during any pressure testing of the gas supply piping system at test pressures 
equal to or less than 1/2 psi (3.5 kPa).    
 
MODEL 
 
 
1110     
 
                        1110  
Gas 
 
 
 
Natural 
 
 
 
Propane 
Maximum 
Heat 
Input 
 10000 
    10000 
Gas Inlet Pressure: 
 
Maximum 
 
10.5 ins. W.C.  
 
 
  13 ins. W.C. 
 
Minimum 
 
 *  5 ins. W.C.  
 
 
*11 ins. W.C. 
Manifold Pressure 
 
  3.5 ins. W.C.  
 
 
    9 ins. W.C. 
 
NOTE:  On initial installation it may be necessary to bleed out air in the gas lines.  Do this by 
holding the control knob and turning the knob to the pilot position for about 30 seconds. 
 
To check the Regulator pressure, remove the pressure tag plug at the left side of the Regulator 
facing the heater.  The pressure should be checked with the heater burning and the control set  
on high.  After measuring the pressure, replace the pressure tap plug,ensuring that there  are no 
leaks. 
*  For the purpose of minimum input adjustment. 
 
                                                       
WARNING 
                         This appliance is equipped for (natural or propane) gas. 
                         Field conversion is not permitted. 
Figure 12 