WARNING 
 
IF YOU SMELL GAS: 
 
 
*  SHUT OFF GAS SUPPLY 
 
 
*  DO NOT TRY TO LIGHT APPLIANCE 
 
 
*  DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY 
 
 
    PHONE  IN YOUR BUILDING 
 
 
*  IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A   
 
 
    NEIGHBOR’S    PHONE.  FOLLOW THE GAS SUPPLIER’S  
 
 
    INSTRUCTIONS. 
 
 
*  IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE 
 
 
    DEPARTMENT. 
 
IMPORTANT:
  Operating heater where impurities in the air exist may create odors.  Cleaning 
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc. 
create fumes.  These fumes may mix with combustion air and create odor. 
OBSERVED 
PROBLEM 
1.  Heater produces a clinking/
ticking noise just after burner 
is lit or shut off 
 
 
2. Heater produces unwanted 
odors 
 
 
 
 
 
 
3.  Heater shuts off in use 
     (ODS operates) 
 
 
 
 
4.  Gas odor even when control 
knob is in “OFF” position 
 
 
 
5.  Gas odor during combustion 
 
POSSIBLE 
CAUSE 
1.  Metal expands while 
heating or contracts while 
cooling. 
 
 
1.  Heater burning vapors 
from paint, hairspray, 
glues, etc.   (See 
Important above) 
2.  Low fuel supply 
3.  Gas leak (See WARNING 
above) 
 
1.  Not enough fresh air is 
available. 
2.  Low line pressure 
3.  ODS/Pilot is partially 
clogged 
 
1.  Gas leak (See 
WARNING, above). 
 
2.  Control valve defect 
 
1.  Foreign matter between 
control valve and burner 
2.  Gas leak (See WARNING 
above). 
SOLUTION 
 
1.  This is common with most 
heaters.  If noise is 
excessive, contact a 
qualified service person. 
 
1.  Ventilate room.  Stop using 
odor causing products 
while heater is running. 
2.  Refill supply tank. 
3.  Locate and control all 
leaks.  See “Checking Gas 
Connections”. 
 
1.  Open window/door for 
ventilation 
2.  Contact local propane co. 
3.  Clean ODS/Pilot 
 
 
1.  Locate and correct all leaks 
(see Checking Gas 
Connections) 
2.  Replace control valve 
 
1.  Remove foreign matter 
from gas tubing 
2.  Locate and correct all leaks 
(see “Checking Gas 
Connections”). 
35