NEC Express 120Mf User Manual

Page of 68
Chapter 4 
Troubleshooting 
If your NEC Express server does not operate as expected, read this chapter before 
assuming a failure. 
NOTE: Troubleshooting and POST error messages refer to 
User Guides. 
POST Error Message List 
On-screen error message 
Description 
Cause 
Action 
0200  Failure Fixed Disk 
Hard disk failure 
1. Incorrect setting in 
Setup 
2. HDD failed 
3. Motherboard failed 
 
1. Check parameters 
entered in Setup 
2. Replace HDD 
3. Replace Motherboard 
0210 Stuck 
Key 
Keyboard connection 
error 
Poor keyboard 
connection 
 
1. Disconnect and reconnect 
keyboard.  
2. Replace keyboard 
3. Replace Motherboard 
0211  Keyboard error 
Keyboard error 
Keybord failed 
Check connection 
0212  Keyboard controller 
Failed 
Keyboard controller 
failure 
Keybord controller 
failed 
1. Check connection 
2. Re-Start 
3. Replace Mother Board 
0213  Keyboard locked - 
Unlock key switch 
Keyboard is locked. 
Keyboard is locked. 
Release Keyboard lock 
0220  Monitor type does not 
match CMOS - Run 
SETUP 
The monitor type is not 
consistent with the 
CMOS data. 
Incorrect monitor type 
setting 
 
1. Reset default values in 
Setup.  
2. Clear CMOS 
0230  System RAM Failed 
at offset 
System RAM error.  
0231  Shadow Ram Failed at 
offset 
Shadow RAM error. 
0232  Extended RAM Failed 
at address line 
Extended RAM error. 
DIMM failed 
1. Replace DIMM 
2. Replace Motherboard 
0250  System battery is dead 
- Replace and run 
SETUP 
The system battery is 
worn out. 
NV-RAM battery 
Replace Motherboard 
0251  System CMOS 
checksum bad - 
Default configuration 
used 
The system CMOS 
checksum is incorrect. 
NVRAM failed 
1. Reset Setup parameters 
2. Replace Motherboard 
0252  Password checksum 
bad - Passwords 
cleared 
The checksum of a 
password is inaccurate.  
 
Password cleared 
 
Reset Setup parameters 
0260  System timer error 
A system timer error 
 
0270  Real time clock error  A real-time clock error  RTC failed 
Replace Motherboard