© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved.    Document #080626002
Kirby Morgan 77
sembly out away from the base of the helmet. Slightly 
loosen the screws until the neck pad  can slide back 
and forth. Be sure each of the head cushion snaps 
are attached to their corresponding  fitting inside the 
helmet.  
Pick up the helmet and pull the nose block device 
knob  out fully. Position the helmet on your head so 
the oral nasal is in the proper position on your face, 
covering your nose and mouth. Turn the sealed pull 
pins to the locking position with the ridge on the pins 
engaging the notch in the sleeve and the pins fully 
retracted. 
Tilt your head forward so the locking collar/neck pad 
assembly may be swung forward and locked up into 
its closed position. The sealed pull pins must snap 
into place on the locking collar.  
Lift your head back up and slide the neck pad forward 
until it is snug but comfortable. Mark the position of 
the neck pad on the locking collar using an indelible 
marker. Pull the sealed pull pins out to their unlocked 
position and let the locking collar open. 
Remove the helmet. Position the neck pad plate on the 
locking collar at the marked position and tighten the 
screws on each side. After the adjustment screws are 
tightened, don the helmet again, tilt your head forward 
and lock the locking collar/neck pad assembly. Move 
your head in various positions to make sure the pad 
is adjusted for comfort.
The helmet is now adjusted for your head. It should 
need no further adjustment unless another diver uses 
the helmet.
3.5 Pre Dress-In Procedure
Before dressing in for a dive, inspection of the helmet 
systems must be made to be sure it is in proper work-
ing order. This must be done well in advance of the 
dive so any problems can be fixed without delaying 
the dive. The following steps are part of the recom-
mended daily maintenance.
3.5.1 Pre-Dive Visual Inspection
Visually inspect the exterior and interior of the hel-
met.
1) Inspect the regulator cover for any damage. The 
purge button must work.
2) The neck dam must not be torn or punctured, and 
properly trimmed to fit.
3) Inspect the O-ring on the neck dam ring assem-
bly. The O-ring must be in place, undamaged, and 
lubricated.
4) Inspect the bent tube that supplies breathing gas 
to the regulator. There must be no dents or kinks in 
the assembly.
5) Inspect the face port. It must be in good condi-
tion.
6) Be sure the communications wires are hooked up 
and tested.
7) Inspect the oral/nasal mask. Make sure it is on 
the  regulator  mount  nut  properly  and  the  valve  is 
installed properly.
8) Inspect the sealed pull pin on each side of the hel-
met. They must engage and disengage properly.
9) Make sure the head cushion  and chin cushion are 
properly fastened inside the helmet. The chin strap 
should be open as wide as possible.
WARNING
There must be no holes in the neck dam. 
If there are any holes in the neck dam the 
helmet  could  leak  or  flood.  In  addition, 
the  demand  regulator  will  not  operate 
properly. Drowning could result.
The O-ring on the neck dam ring assem-
bly on the Kirby Morgan helmet must be 
in place and in good condition.  It must 
be properly lubricated for smooth opera-
tion. Without a proper functioning O-ring 
the helmet will leak and possibly flood. 
Drowning could result.
WARNING