MiTAC 7521 PLUS/N User Manual

Page of 180
107
7521
7521
Plus / N  N/B  MAINTENANCE
Plus / N  N/B  MAINTENANCE
Symptom:
Symptom:
When the power button is pressed, nothing happens, no fan activi
When the power button is pressed, nothing happens, no fan activi
ty is heard and power indicator is not light up
ty is heard and power indicator is not light up
.
8.1 NO POWER:
.
CONTINUE
2. Check the power source
from AC adapter. (PJ501)
PL501
PF501
PC2
PC509   PR15   PR16
PD501   PR14   PD3
PU2       PR13 ……..       
SIGNAL:
PARTS:
ADINP
LEARING
POWER
OK?
END
NO
If “D/VMAIN”
failure.
CHECK: 
PD3,PD4,PL3,PR20,PR21,PQ12,
PU9,PR23,PC58,PC57…….
CHECK : 
PD1,PD2,F2,U32,C247,Q22....
If “VDD5”
failure.
If “VCC_CORE”
(CPUVCC)
failure.
CHECK: 
PL12,PU18,PU12,PU19,PU20,
PU22,PU23,PL11,PD21,PR79,
PR80,PC122,PC119,PC123,….
CHECK : 
PU10,PQ502,PQ503,PQ7,
PQ9,PL504,PD505,PU501,
PD502,PL503,PR1,PL502,
PR3,PD504…….
If  “+S12V, +S5V_P
or +S3V_P” failure.
YES
CHECK: 
PU14,PU4,PU5,PD7,PD8,PD10,
PD11,PD15,PL5,PL6,PR32,PR35
,PR46,PR47,PR41,PR42….
If “1.5V, 1.8V”
Failure.