Hotpoint RB787WH/CH/BH Leaflet

Page of 2
®
Specification Revised 11/05 
420487
RB787WH/CH/BH – Hotpoint 30" Free-Standing Electric Range 
Dimensions (in inches)
R
Listed by 
Underwriters 
Laboratories
All Hotpoint ranges are equipped 
with an Anti-Tip device. The 
installation of this device is 
an important, required step in  
the installation of the range.
26-3/8*
46-3/8
1/4
29-7/8
46-1/2
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
26-3/8*
46-3/8
1/4
29-7/8
46-1/2
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
Note: Check local codes for required breaker size.
Effective January 1, 1996, the National Electrical Code requires that new con-
struction (not existing) utilize a 4-conductor connection to an electric range. 
Note: 30" Electric Ranges conform to U.L. requirements for 0" spacing from 
walls below countertops. Allow 1-1/2" spacing from the side of the range to 
adjacent vertical walls above the cooktop surface.
Receptacle Locations: Locally approved flexible service cord or conduit 
must be used because terminals are not accessible after range installation. 
See shaded area in drawing for location of electrical outlet box. Recommended 
outlet locations allow range to be installed directly against rear wall.
Installation Information: Before installing, consult installation instructions 
packed with product for current dimensional data. 
 
 KW Rating
  240V
 
10.5
  208V 
7.9
Breaker Size
 
40 Amps
* Dimension from wall to front of closed oven door. 
Dimension from wall to the front of closed oven  
door handle is 28-1/2".
The range may be placed with
0" clearance (flush) at the back  
wall and side walls if the range side 
trims extend beyond the  
cabinet fronts at least 1/4". 
Self-Clean models only