Installation must be done in
accordance with all local and
national codes.
Use only materials which
Use only materials which
conform to local codes in
effect. Be sure power is
disconnected before doing
any electrical work. All duct
work must be metal.
Do not use plastic duct.
Do not use plastic duct.
The range hood should
never be exhausted into
a wall cavity or an attic
where an accumulation of
grease could become a fire
hazard.
When the installation is
When the installation is
completed, turn on the fan
and make sure that there are
no obstructions in the duct.
30" Model
48" model
Venting Safety Guidelines
Vented Installation, Tools, Material, and Dimensions
Tools required to install vented hood:
- Hammer
- Slot screwdriver
-
Pliers
-
Electric
drill
- Measuring tape
- 3/32” (3 mm) Drill bit
- 1/2” (13 mm) Drill bit - Sabre saw OR Keyhole saw
Materials Required:
- 3 1/4" x 10" (82.55 mm x 254 mm) metal duct—enough to go through wall or attic to outside. Elbows as required.
- Roof cap or wall venthood
- Caulking to seal around duct
- #6 x 1/2” (82.55 mm x 254 mm) sheet metal screws
The above are standard parts and are available at any hardware store or heating contractor.
NOTE: A 3 1/4" x 10" (82.55 mm x 254 mm) exhaust adaptor is included with the exhaust hood.
52”
(132 cm)
with bottom drawer fully open
43-3/4”
(111 cm)
with oven
door open
0” clearance
to the back
3” (7.6 cm)
14”
(36 cm)
29-1/2”
(75 cm)
56”
(142 cm)
36-1/8”
(92 cm)
47-1/2”
(121 cm)
39-3/4”
(101 cm)
66-1/4”
(168 cm)
20”
(51 cm)
Range Hood Outlet
3-1/4” x 10”
(8.3 x 25.4 cm)
Oven
Exhaust
Power
Cord
Exhaust
Hood
Receptacle
52”
(132 cm)
with bottom drawer fully open
43-3/4”
(111 cm)
with oven
door open
0” clearance
to the back
3” (7.6 cm)
14”
(36 cm)
29-1/2”
(75 cm)
Range Hood Outlet
3 1/4"x10"
8.3 cm x 25.4 cm
66 1/4"
168.3 cm
62 3/8"
159 cm
56"
142.2 cm
36 1/8"
92 cm
29 3/4"
76 cm
13 3/4"
35 cm