Before operating this heater, please review the safety warnings 
pages at the beginning of this manual and those precautions and 
warnings listed below.
1.  Know what type of ignition system this model has (standing 
pilot)  and  follow  the  applicable  SAFETY  and  LIGHTING 
instructions.
2.  Check to ensure there are no gas leaks. If you are unsure, 
turn gas off to the heater and call a service person or your gas 
utility.
CAUTION: Clothing or other flammable material should not 
be placed on or near the appliance.
WARNING: Children and adults should be alerted to the 
hazard of high surface temperature and should stay away 
to avoid burns or clothing ignition. Young children should 
be carefully supervised when they are in the same room 
as the appliance.
3.  Tampering is DANGEROUS and voids all warranties. Any 
component that is found to be faulty, must be replaced with 
an approved component.
Initial Lighting (Figure 14)
Upon completing the gas line or turning the gas valve "ON" after it 
has been in the "OFF" position, a small amount of air will be in the 
lines. When first lighting the appliance, it will take a few minutes 
for the lines to purge themselves of this air. Once the purging is 
complete, the appliance will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging 
if the gas valve is not turned to "OFF."
Standing Pilot Operation
1.  Follow the SAFETY and LIGHTING INSTRUCTIONS for 
standing pilot controls found in this manual and on labels found 
attached to the appliance.
CAUTION:  During  the  initial  purging  and  subsequent 
lightings, never allow the gas valve control knob to remain 
depressed in the "pilot" position without pushing the piezo 
ignitor button at least once every second. 
2.  During the heating season, leave the control valve knob in the 
"ON" position. This will allow the pilot flame to remain lit. 
Turn the burner flame on or off with the appliance ON/OFF 
rocker switch, wall switch, remote control kits or 750 millivolt 
wall thermostat.
NOTE: The gas control valve allows you to increase or decrease the 
height of the main burner flame. The control valve has a pressure 
regulator with a knob as shown in Figure 14. Rotate the knob 
clockwise to "HI" to increase the flame height and counterclockwise 
to "LO" to decrease the flame height.
3.  When the heating season is over, turn the on/off switch to 
"OFF" and the control valve to "OFF". The system, including 
the pilot light, will be shut down.
Figure 14
Maximum and Minimum Input
The gas valve on the appliance allows the input to adjust between 
a maximum input of 30,000 to a minimum input of 21,000 Btuh. 
Please be advised, the maximum input provides the greatest amount 
of yellow flame and ember glow on the log set. The minimum 
input substantially decreases the yellow flame and ember glow 
on the log set.
This heater must be properly connected to a venting system. This 
heater is equipped with a vent safety shutoff system.
Warning: 
Operation of this heater, when not connected to a properly 
installed  and  maintained  venting  system  or  tampering 
with the vent safety shutoff system, can result in carbon 
monoxide (CO) poisoning and possible death.
This appliance needs fresh air for safe operation and must be 
installed  so  there  are  provisions  for  adequate  combustion  and 
ventilation air.
This fireplace heater is equipped with a vent safety switch. The 
vent safety switch will cause gas flow to the pilot to "shut off" 
due to improper venting or a blocked flue.
If the vent safety switch continues to "shut off" the gas flow to 
the pilot a qualified service person must be contacted to inspect 
for improper venting, blockage in the vent pipe or the vent safety 
switch for being defective. 
Reversible Vertical or Horizontal Draft Diverter
This  fireplace  heater  has  a  reversible  draft  diverter.  The  draft 
diverter is  installed in the vertical position at the factory. Please 
use the following steps to change the draft diverter from the vertical 
position to the horizontal position.
1.  Remove (8) hex-head screws located adjacent to the flue collar 
on the draft diverter.
2.  Rotate  flue  collar  to  the  horizontal  position  on  the  draft 
diverter.
3.  Attach flue collar to draft diverter with (8) hex-head screws from 
Step 1.
OPERATING GUIDELINES
VENT SAFETY SHUTOFF SYSTEM