Fujitronic Programmable Operation Display UG520H-x User Manual

Page of 275
2 - 8
FUJI PLC • 4
(FLEX-PC series)
Available PLC
*
1
When FLEX-PC TOYOTA version is used, select “FLEX-PC(T)” in [PLC Type].
Communication Setting
The recommended communication parameter setting of both PLC and POD is as follows:
4
RS-232C [Wiring Diagram 1]
RS-485 [Wiring Diagram 2]
NS Series, NS-T
NJ-RS2
NJ-RS4
NS-RS1
RS-232C [Wiring Diagram 1]
RS-485 [Wiring Diagram 2]
NJ Series, NJ-T
FLEX-PC
Series
PLC
Select PLC Type
NB-RS1
RS-232C [Wiring Diagram 1]
RS-485 [Wiring Diagram 2]
NB Series
*
 1
Wiring Diagram
Link Unit
Port
Transmission
Control Mode
RS-232C
RS-422
0
19200bps
Even
7 (ASCII)
Baud Rate
Parity
Transmission
Code
Data Length
Stop Bit
1
Terminal Resistor at Receiver
Item
Setting of PLC
0
19200bps
 Even
7
1
Comm. Parameter of POD
Provided for RS-485
1 (Asynchronous non-protocol by command)(fixed)
3 (Asynchronous non-protocol by command)(fixed)
3 FUJI PLC 