4. Operating Instructions 
15 
10/27/2009 1:10 PM 
Setting the Starting Address 
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address 
from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start 
on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start 
addresses so that the channels used do not overlap, and note the start address selected for future reference. 
If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the 
“Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you 
understand its use. 
General Troubleshooting  
S
YMPTOM
 
P
OSSIBLE 
C
AUSE
(
S
P
OSSIBLE 
A
CTION
(
S
Breaker/Fuse 
keeps blowing 
  Excessive circuit load 
  Check total load placed on the electrical circuit. 
  Short circuit along the power 
wires 
  Check for a short in the electrical wiring (internal and/or 
external). 
Device does not 
power up 
  No power 
  Check for power on Mains. 
  Loose power cord 
  Check power cord 
Fixture is not 
responding to 
DMX 
  Wrong DMX addressing 
  Check Control Panel and unit addressing  
  Damaged DMX cables 
  Check DMX cables 
  Wrong polarity settings on the 
controller 
  Check polarity switch settings on the controller 
  Loose DMX cables 
  Check cable connections 
  Faulty DMX interface 
  Replace DMX input 
  Faulty Main PCB 
  Replace Main PCB 
Loss of signal 
  Non DMX cables 
  Use only DMX compatible cables 
  Bouncing signals 
  Install terminator as suggested. 
  Long cable / Low level signal 
  Install amplifier right after fixture with strong signal.  
  Too many fixtures 
  Install an optically coupled DMX splitter after unit #32. 
  Interference from AC wires 
  Keep DMX cables separated from power cables or 
black lights. 
 
If you still have a problem after trying the above solutions, please contact CHAUVET Technical 
Support. 
 
Contact Us 
W o r l d   W i d e  
General Information 
CHAUVET 
3000 North 29
th
 Court 
Hollywood, FL 33020 
voice: 
954.929.1115 
fax: 
954.929.5560 
toll free:  800.762.1084 
Technical Support 
CHAUVET 
3000 North 29
th
 Court 
Hollywood, FL 33020 
voice: 
954.929.1115 (Press 4)  
fax: 
954.929.5560 (Attention: Service) 
World Wide Web 
www.chauvetlighting.com