Campbell Manufacturing TEMPERATURE PROBE 109SS User Manual

Page of 18
Model 109SS Temperature Probe 
5.1.1.1  Sample Program for CR200 Series Datalogger 
'CR200 Series Datalogger 
 
‘This example program measures a single 109SS Thermistor Probe  
‘once a second and stores the average temperature every 10 minutes. 
 
‘Declare the variable for the temperature measurement 
Public Air_Temp 
 
‘Define a data table for 10 minute averages: 
DataTable (AvgTemp,1,1000) 
 DataInterval 
(0,10,min) 
 Average 
(1,Air_Temp,0) 
EndTable 
 
BeginProg 
 
Scan (1 ,sec) 
 
 
‘Measure the temperature: 
  Therm109 
(Air_Temp,1,1,Ex1,1.0,0) 
 
 
Call the data table: 
  CallTable 
AvgTemp 
 NextScan 
EndProg 
 
5.1.1.2  Example 2.  Sample Program for CR1000 Datalogger 
'CR1000 
 
'Declare Variables and Units 
Public T109_C 
 
Units T109_C=Deg C 
 
'Define Data Tables 
DataTable(Table1,True,-1) 
 DataInterval(0,10,Min,10) 
 Average(1,T109_C,FP2,False) 
EndTable 
 
'Main Program 
BeginProg 
 Scan(1,Sec,1,0) 
 
 
'Default Datalogger Battery Voltage measurement Batt_Volt: 
 
 
'109SS Temperature Probe measurement T109_C: 
  Therm109(T109_C,1,1,1,0,_60Hz,1.0,0.0) 
 
 
'Call Data Tables and Store Data 
  CallTable(Table1) 
 NextScan 
EndProg