Description
MP 44 Use
The MP 44's REMOTE LEVEL port provides a means to 
control the level of the MASTER mix from a remote location. 
The range of control is 0 dB to -40 dB. Applications include 
”gain riding” DJs, setting a comfortable listening level from a 
remote location and reducing the maximum available gain.
DA 26 Use
A port for a wired Remote Level control is provided for each 
of the six Outputs. Using the optional VR 1 Remote control pro-
vides an audio taper response from 0 dB to > -80 dB. To control 
more than one Remote Port with a single Remote control, it is only 
necessary to connect the Vc pin of each additional port.
Voltages
Turn the power to the unit off until all connections are made. 
It is important to ensure that the Remote Ports are not subjected 
to sustained voltages outside the range of 0 to 5 VDC or high 
levels of static. Inputs are protected, however, caution is the 
better part of... you know. It is a good idea to install the wiring, 
connect it to the Remote and then make the final connections at 
the Remote Port.
Do not short the Vr pin to ground. This pin is current lim-
ited; however, excess heat is generated in the 5 V supply if a short 
occurs. Never subject the Vr pin to voltages above 5 V.
Remote Mounting
The VR 1 remote assembly mounts in a standard U.S. electri-
cal box with a minimum depth of 2.25" (5.5 cm). Use the flat 
head #6 screws supplied with the kit to mount the remote assem-
bly and silk-screened front panel to the electrical box.
Install the knob so that the line on the knob is properly 
aligned with the silk-screening on the front panel of the remote. 
Install any Decora plate of your choice. For a secured installa-
tion, you may wish to leave the knobs off and use a blank Decora 
plate to cover the remote after adjustment.
Euroblock Connections
Be sure to note the wire color of each input in order to facili-
tate correct wiring to the controlled unit. If the ground or shield 
wire is left shorter, it acts as a strain relief for the other wires. 
Connect each wire to the 3-pin connector by fully inserting it in 
the correct socket and tightening the screw. Make sure wires are 
free of nicks and that the cable jacket is stripped back sufficiently 
to allow it to lie in the electrical box with the remote assembly 
inserted. 
Vc
GND
Vr
4
0
2
6
8
10
LEVEL