-20- 
Devices  A and B are located in different  networks. Users  want to use  them to 
form a logical network. 
In this case, using the Security pushbutton cannot pair Devices A and B. Users 
can only use the Utility to form a logical network. 
Please follow below to form a logical network using the Utility: 
1.  Connect Device A to the network card of a PC. 
2.  Open  the  Utility.  The  Main  tab  page  displays  information  about  Device  A 
after connection succeeds. 
 
Search for Local device on your computer 
3.  Click the Privacy tab page. Enter a name in the Private Network Name field. 
 
Setting the network name for your PLC 
4.  Click  Set  Local  Device  Only.  When  the  following  page  is  displayed,  the 
setting succeeds. Now Device A has been removed from its logical network.