39. Replacement of Fuses and Lamps
T h e   t w o   f u s e s   ( F 1   a n d   F 2 )   a n d   t h e   t w o   g l o w l a m p s   ( 1 1 C   a n d
1 2 C )   a r e   r e m o v a b l e   f r o m   t h e   f r o n t   p a n e l   o f   t h e   t u b e   t e s t e r .
a .   R e p l a c e m e n t   o f   F u s e s .   F u s e s   F 1   a n d   F 2   a r e   3 - a m p e r e ,   2 5 0 -
v o l t ,   ¼ -   b y   1 ¼ - i n c h ,   c a r t r i d g e - t y p e   f u s e s   ( f i g .   5 ) .   T o   r e m o v e   a
f u s e ,   p r e s s   t h e   f u s e h o l d e r   c a p   a n d   t u r n   i t   c o u n t e r c l o c k w i s e .   R e -
move the cap, and then remove the fuse from its holder.
C a u t i o n :   The fuses are rated at 3 amperes each. When replac-
ing a fuse, be careful to use a fuse of the same rating.
b .   R e p l a c e m e n t   o f   L a m p s .   L a m p s   1 1 C   a n d   1 2 C   a r e   g l o w l a m p s
( f i g .   1 )   w i t h   m i n i a t u r e - b a y o n e t   b a s e s .   T o   r e m o v e   a   g l o w l a m p ,
u n s c r e w   t h e   i n d i c a t o r   l i g h t   l e n s ,   p r e s s   t h e   l a m p   i n w a r d   a n d
r o t a t e   i t   c o u n t e r c l o c k w i s e ,   a n d   w i t h d r a w   t h e   g l o w l a m p   f r o m   i t s
s o c k e t .