1.  Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the 
way when the venting system is attached. If this is the case, you may want to adjust the location of 
the appliance.
2.  Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired 
combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the 
wall or floor, as much out of view as possible.
 
Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a bead 
of high temperature silicone on the male edge of the outer pipe. Push the pipe sections completely 
together, then twist-lock one section clockwise approximately 1⁄4 turn, until the two sections are fully 
locked. The female locking lugs will not be visible from the outside, on black pipe. They may be 
located by examining the inside of the female ends as shown in Figure 23.
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 24: Twist-Lock Connection
Woodscrews
Wall Thimble
Strap
Sheet metal
screws
Fold strap
here
1
1
/
4
"
(3.2cm)
Figure 26: Installing Decorative Wall Thimble.
���
�������
���
�������
Figure 25: Wall Framing Hole 
for Horizontal Installation. 
Initial Installation
QUALIFIED INSTALLERS ONLY
3.  With 
the 
pipe 
attached  to  the 
stove in the correct 
location,  mark  the 
wall for a 10” (25.4 
cm)  x  10”  (25.4 
cm)  square  hole 
(refer  to  Figure 
25).  The  center  of 
the  square  hole 
should  match  the 
center  line  of  the 
horizontal 
pipe. 
Cut  and  frame  the 
10” (25.4 cm) x 10” 
Notes:
 
•  Twist-lock  procedure:  four  (4) 
indentations,  located  on  the  female 
end  of  the  pipes  and  fittings,  are 
designed  to  slide  straight  onto  the 
male  ends  of  adjacent  pipes  and 
fittings,  by  orienting  the  four  pipe 
indentations so they match and slide 
into the four entry slots on the male 
end.
•  Horizontal runs of vent pipe must be 
supported every three ft. Wall straps 
are  available  for  this  purpose,  also 
when  running  horizontal  pipe  minimum  clearances  to  combustibles 
must be maintained; 2 inches (5.1 cm) at top, 11⁄2 inches (3.8 
cm) at sides, 11⁄2 inches (3.8 cm) at bottom.
(25.4 cm) hole in the exterior wall where the vent will be terminated. If the wall being penetrated 
is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole is 
acceptable.