Sherwood Enviro EG40 DV User Manual

Page of 39
Figure 4: Gas Valve.
Figure 3: Pilot Burning.
7
•  There  is  a  separate  venturies  for  each  burner, 
see Figure 5.
•  Remove one screw from the cover plate located 
below the ash shelf and loosen the other screw 
(do not remove) swing the cover plate out of the 
way and tighten screw down to hold it in place.
•  With along screwdriver rotate spring clips to open 
or close the venturies to the desired setting.
The venturies allows the amount of air coming into 
the fireplace to be adjusted in order to accommodate 
different climates and venting arrangements. Start 
Operating Instructions
Gold bar
Screwdriver
Rear log holder
Front log holder Ember tray &
front burner
Venturies
Door
Rear burner
Air shutter cover plate
Figure 5: Venturi Adjustment.
the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports 
are plugged. Let the fireplace burn for roughly fifteen9minutes and then examine the flames, compare 
the flames to Figure 16.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. 
If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, 
the fireplace is getting too much air. Therefore, the venturies should be closed slightly until the correct 
flames are achieved.  Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. 
Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct 
flames cannot be attained, turn off the gas and contact the dealer.
Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. 
Contact the dealer if there is any concern about the venturi adjustment.
N
ORMAL
 S
OUNDS
 D
URING
 O
PERATION
:
Table 1: Normal Sounds
Component
Sound & Reason
EG40
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The 
blower is pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
A
DJUSTING
 T
HE
 V
ENTURIES
: