Siemens TV Converter Box 611 User Manual

Page of 324
Technical data and characteristics 
 
14.1 Explanations of the formula abbreviations 
Boundary conditions  
 
U
ZK
 
Converter DC link voltage (direct voltage value). 
Comment: For converter output voltages U
amax
: see "System requirements". 
T
VORL
 
Maximum intake temperature of the water cooler for the main cooler and 
precision cooler if the motor is to be utilized up to its rated torque M
N
. For 
details of the dependency of the continuous motor current on intake 
temperature of the water cooler, see the characteristic curve in "Cooling". 
T
N
 
Rated temperature of the motor winding. 
Rated data 
 
M
N
 
Rated torque of the motor. 
I
N
 
Rated motor current at the rated torque M
N
 
n
MAX,MN
 
Maximum speed up to which the motor can deliver the rated torque M
N
P
V,N
 
Power loss of the motor at the rated point (M
N
,n
MAX,MN
) at the rated temperature 
T
N
Limit data 
 
M
MAX
 
Maximum motor torque. 
I
MAX
 
Maximum motor current at maximum torque M
MAX
. Maximum possible load 
duration: see "Short-time duty S2". 
P
EL,MAX
 
Electric power input of the motor at point (M
MAX
,n
MAX,MMAX
) at rated temperature 
T
N
 
 
 
Note 
The sum of the mechanical output P
mech
 and the power loss P
V
 equals the electric power 
input of the motor P
EL
See also "Calculating the required infeed power". 
The electrical rated power of the motor at the rated point with M = M
N
 and n = n
MAX,MN
can be 
calculated as follows: 
P
EL,N
 = P
mech,N
 + P
V,N
 = 2π ∙ M
N
 ∙ n
MAX,MN
 + 3 ∙ R
130
 ∙ I
02
 
Frictional and eddy current losses are taken into account by using the larger current I
0
 in the 
calculation instead of I
N
 
 
 
 
1FW6 Built-in torque motors 
198
 