Technical data and characteristics 
 
14.2 Data sheets and diagrams 
Data sheet 1FW6130-xxB15-xxxx 
Table 14- 8  1FW6130-xxB15-1Jxx, 1FW6130-xxB15-2Jxx 
Technical data 
1FW6130 
Symbol 
Unit 
-xxB15-1Jxx  -xxB15-2Jxx   
Boundary conditions 
 
 
 
 
 
DC link voltages 
U
ZK
 
600 
600 
 
Water cooling inlet temperature 
T
VORL
 
°C 
35 
35 
 
Rated temperature of winding 
T
N
 
°C 
130 
130 
 
Rated data 
 
 
 
 
 
Rated torque 
M
N
 
Nm 
744 
714 
 
Rated current 
I
N
 
18 
26 
 
Maximum speed at rated torque 
n
MAX,MN
 
rpm 
78 
150 
 
Rated power dissipation 
P
V,N
 
kW 
6.81 
6.81 
 
Limit data 
 
 
 
 
 
Maximum torque 
M
MAX
 
Nm 
1320 
1320 
 
Maximum current 
I
MAX
 
36 
54 
 
Electric power of motor at M
MAX
 
P
EL,MAX
 
kW 
25.4 
34.1 
 
Maximum speed at maximum torque 
n
MAX,MMAX
  rpm 
14 
77 
 
No-load speed 
n
MAX,0
 
rpm 
160 
240 
 
Torque at n = 1 [rpm] 
M
0
 
Nm 
775 
775 
 
Current at M
0
 and n = 1 [rpm] 
I
0
 
19 
29 
 
Thermal static torque 
M
0
Nm 
548 
548 
 
Thermal stall current 
I
0
13 
20 
 
Physical constants 
 
 
 
 
 
Torque constant at 20 °C 
k
T,20
 
Nm/A 
40.9 
27.3 
 
Voltage constant 
k
E
 
V/(1000/min) 
2475 
1650 
 
Motor constant at 20 °C 
k
M,20
 
Nm/(W)
0.5
 
9.69 
9.69 
 
Thermal time constant 
t
TH
 
60 
60 
 
No. of pole pairs 
33 
33 
 
Cogging torque 
M
COG
 
Nm 
3.9 
3.9 
 
Stator mass 
m
S
 
kg 
24.7 
24.7 
 
Rotor mass 
m
L
 
kg 
13.5 
13.5 
 
Rotor moment of inertia 
J
L
 
10
-2
 kgm
2
 
19.1 
19.1 
 
Phase resistance of winding at 20 °C 
R
STR, 20
 
Ω 
4.27 
1.9 
 
Phase inductance of winding 
L
STR
 
mH 
13.9 
6.2 
 
Data, main motor cooler 
 
 
 
 
 
Maximum dissipated thermal power 
Q
H,MAX
 
kW 
5.67 
5.67 
 
Recommended minimum volume flow rate 
H,MIN
 
l/min 
9.8 
9.8 
 
Temperature increase of the coolant 
ΔT
H
 
8.3 
8.3 
 
Pressure drop 
Δp
H
 
bar 
0.6 
0.6 
 
 
1FW6 Built-in torque motors 
218
 