Siemens TV Converter Box 611 User Manual
Technical data and characteristics
14.2 Data sheets and diagrams
Data sheet 1FW6150-xxB07-xxxx
Table 14- 10 1FW6150-xxB07-2Jxx, 1FW6150-xxB07-4Fxx
Technical data
1FW6150
1FW6150
Symbol
Unit
-xxB07-2Jxx -xxB07-4Fxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
470
445
Rated current
I
N
A
25
38
Maximum speed at rated torque
n
MAX,MN
rpm
260
450
Rated power dissipation
P
V,N
kW
3.28
3.23
Limit data
Maximum torque
M
MAX
Nm
994
994
Maximum current
I
MAX
A
66
100
Electric power of motor at M
MAX
P
EL,MAX
kW
32
42.7
Maximum speed at maximum torque
n
MAX,MMAX
rpm
130
230
No-load speed
n
MAX,0
rpm
370
600
Torque at n = 1 [rpm]
M
0
Nm
504
504
Current at M
0
and n = 1 [rpm]
I
0
A
27
44
Thermal static torque
M
0
*
Nm
356
356
Thermal stall current
I
0
*
A
19
30
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
18.5
11.6
Voltage constant
k
E
V/(1000/min)
1119
699.4
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
8.91
8.99
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
33
33
Cogging torque
M
COG
Nm
2.5
2.5
Stator mass
m
S
kg
24.7
24.7
Rotor mass
m
L
kg
8.8
8.8
Rotor moment of inertia
J
L
10
-2
kgm
2
14.2
14.2
Phase resistance of winding at 20 °C
R
STR, 20
Ω
1.03
0.396
Phase inductance of winding
L
STR
mH
5.8
2.3
Data, main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
2.73
2.68
Recommended minimum volume flow rate
H,MIN
l/min
6.5
6.5
Temperature increase of the coolant
ΔT
H
K
6
5.9
Pressure drop
Δp
H
bar
0.4
0.4
1FW6 Built-in torque motors
222
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7