Siemens TV Converter Box 611 User Manual
Description of the motor
2.2 Technical features
Ambient conditions for long-term storage, transport, and use in fixed locations
Based on DIN EN 60721-3-1 (for long-term storage), DIN EN 60721-3-2 (for transport), and
DIN EN 60721-3-3 (for use in fixed, weather-protected locations)
Table 2- 2
Climatic ambient conditions
Lower air temperature limit:
- 5 °C
Upper air temperature limit:
+ 40 °C (deviates from 3K5)
Lower relative humidity limit:
5 %
Upper relative humidity limit:
85 %
Rate of temperature fluctuations:
< 0.5 K/min
Condensation:
Not permissible
Formation of ice:
Not permissible
Long-term storage:
Class 1K3 and class 1Z1 have a different upper relative humidity
Transport:
Class 2K2
Fixed location:
Class 3K3
Storage, transport and operation permissible only in locations that are fully protected against the weather
(in halls or rooms).
(in halls or rooms).
Table 2- 3
Biological ambient conditions
Long-term storage:
Class 1B1
Transport:
Class 2B1
Fixed location:
Class 3B1
Table 2- 4
Chemical ambient conditions
Long-term storage:
Class 1C1
Transport:
Class 2C1
Fixed location:
Class 3C2
Operating site in the immediate vicinity of industrial plants with chemical emissions
Operating site in the immediate vicinity of industrial plants with chemical emissions
Table 2- 5
Mechanically active ambient conditions
Long-term storage:
Class 1S2
Transport:
Class 2S2
Fixed location:
Class 3S1
1FW6 Built-in torque motors
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
27