Siemens TV Converter Box 611 User Manual

Page of 324
 
Motor components of the built-in motor and options 
 
3.2 Thermal motor protection 
Table 3- 3 
Technical data of the KTY 84 PTC thermistor 
Name 
Description 
Type 
KTY 84 
Transfer range 
- 40 °C ... + 300 °C 
Resistance when cold (20 °C) 
approx. 580 Ω 
Resistance when hot (100 °C) 
approx. 1000 Ω 
Connected via the SME9x module Connect the signal cable with connector to the SME9x module. 
Connection via a multimeter with 
a high voltage strength 
(alternatively) 
A multimeter (V >1000 V) can also be used for evaluation. 
Application 
Temperature monitoring to determine the motor utilization. 
Temperature characteristic 
 
5HVLVWDQFH˖
7HPSHUDWXUHr&
,7HVW P$







  
               
 
 
 
 
DANGER 
 
Electrical shock hazard! 
Signal cable: Conductor wh and conductor bn may not be directly evaluated via the drive 
converter for reasons associated with safety isolation according to EN 61800-5-1 
(previously, safe isolation according to VDE 0160 / EN 50178). 
 
 
 
NOTICE 
 
When connecting temperature sensors with open cable ends, please pay attention to how 
the core colors are assigned (described in the section dealing with connections). 
 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7 