Configuring the motor 
 
5.3 Short-time duty S2 and intermittent duty S3 
5.3 
Short-time duty S2 and intermittent duty S3 
Short-time duty S2 
In the case of short-time duty S2, the load time is so short that the final thermal state is not 
reached. The subsequent zero-current break is so long that the motor practically cools down 
completely. 
 
CAUTION 
 
An excessive load can lead to the destruction of the motor. 
The load may not exceed the value I
MAX
 specified in the data sheets! 
 
The motor may only be operated for a limited time t < t
MAX
 with a current I
N
 < I
M
 ≤ I
MAX
. The 
time t
MAX
 can be calculated using the following logarithmic formula:  
W
0$;
 W
7+
yOQ
Y
Y

 
with ν = (I
M
 / I
N
)
2
 and the thermal time constant t
TH
The thermal time constants, the maximum currents and the rated currents of the motors can 
be taken from the data sheets. 
 
 
Note 
The above equation applies with the prerequisite that the starting temperature of the motor is 
the same as the intake temperature of the water cooling system T
VORL
 in accordance with the 
data sheet. 
 
Example 
Motor 1FW6190-xxx15-2Jxx is to be operated from a cold state at maximum current. 
●  I
MAX
 = 47 A, I
N
 = 26 A; this results in ν = 3.268 
●  t
TH
 = 180 s 
 
 
The motor can be operated for a maximum of 66 s at maximum current. 
 
1FW6 Built-in torque motors 
78
 