Sigma BSG26N Service Manual

Page of 5
 
SIGMA ELECTRONICS, INC. 
BSG-26 SERIES 
 
SERVICE MANUAL 
 
CAUTION 
 
These servicing instructions are for use by qualified personnel only. To reduce the risk of 
electric shock do not perform any servicing other than that contained in the operating instructions 
unless you are qualified to do so. Refer all servicing to qualified service personnel. 
 
Explanation of symbols used. The following symbols appear on the product. 
 
 
 
 
 
 
DANGER 
ATTENTION 
Protective Ground 
Fuse Replacement  
AC 
  High Voltage 
Refer to Manual 
(earth) Terminal   RISK OF FIRE REPLACE  
Power 
 
 
 
 
FUSE AS MARKED 
 
 
Read the IMPORTANT SAFETY INSTRUCTIONS before installing or operating this equipment. Keep this 
information in an accessible location for reference by all users. Follow all instructions in this manual for safe operation. 
 
JUMPERS: 
 
The following jumpers are located on the PCB inside the enclosure. They are provided for custom 
configuration of the BSG-26N and BSG-26P. The modules should not require any adjustments for normal Black Signal 
operation. 
J1  Superblack/Black Select, Default position, Pins 2-3 (Black), Optional position, Pins 1-2 (Superblack). 
J2  Setup On/Off, Default position 1-2 (Setup On, NTSC, BSG-26N), Position 2-3 (Setup Off, PAL, BSG-26P) 
J3 Subcarrier Phase Select, 0
°
 or 180
°
, Default position is 0
°
, Opposite position is 180
°
 
 
ADJUSTMENTS: 
 
The following adjustments are located on the PCB inside the enclosure. They are provided for custom 
configuration of the BSG-26N and BSG-26P. The modules should not require any adjustments for normal Black Signal 
operation. 
C31  Subcarrier center frequency. 
R7  Sync./Setup Gain, Set per standards specified. 
R14  Subcarrier Null, Minimizes residual subcarrier on output signal. 
R20  Burst Gain, Set per standards specified. 
R22 Variable Subcarrier Phase Adjust, 180
°
 SCH Phase adjust, See “JUMPER” section, jumper 3 options. 
R25 Subcarrier Symmetry, Provides minimum difference in duty cycle between 0
°
 and 180
°
 setting of J3 
 
DISASSEMBLY: 
 
NOTE: REMOVE THE POWER BEFORE DISASSEMBLY OF THE UNIT. 
 
Disassembly is not necessary for normal Black Signal operation
Tools needed: 
#1 Phillips head screw driver. 
Procedure:  1st, remove the four rear panel Phillips head machine screws, one per corner. 2nd, remove the 
electrical assembly by pulling the rear panel from the enclosure; the PCB is attached to the rear panel. 
 
TECHNICAL MANUAL: 
 
A manual including schematics, circuit description, parts list and setup guide is available upon request. This 
information is intended for the service of the unit. The units should be serviced by qualified personnel only. Sigma 
Electronics, Inc. recommends service to be performed by the Factory Service Center. 
 
4 OF 4