Pelco PelcoNet NET300 Multimedia Transmission Via Network C2908M-B User Manual

Page of 96
C2908M-B (4/05)
85
CONNECTING PELCONET TO A CM9760-DT FOR REMOTE BROWSER CONTROL
Figure 51.  Using PelcoNet with CM9760-DT to Provide Remote Control of a 9760 Monitor Output
TRANSMITTER
MON OUTPUT
TIE LINE
CM9505-UPS
CM9760KBD
ETHERNET
CONNECTION
TO NETWORK
(LAN/WAN)
CM9760-CC1
CM9760-MXB
SPECTRA P
PROTOCOL
SUPPLIED
CABLE
CM9760-DT1
2-RX
3-TX
5-GND
2-RX
3-TX
5-GND
1 ON
2 OFF
DIP SWITCH
NULL MODEM CABLE
NOT SUPPLIED
COM 2 PROGRAMMED FOR 9760-DT
COM 1
COM 2
NOTE:  4800 BAUD AND EVEN PARITY APPLIES
TO CM9760-DT VERSION 2.07, WHILE
9600 BAUD AND ODD PARITY APPLIES
TO VERSION 3.0
PELCONET CM9760-DT SETUP
TRANSPARENT DATA PORT
USING INTERNET EXPLORER;
SET TRANSPARENT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
4800 OR 9600
8
EVEN OR ODD
1
RS232/422/485
Video In
MONITOR
SPECTRA