Nortel Networks NN46200-301 User Manual

Page of 28
24
Appendix Electrical specifications for the AC power supply
Note the following information:
The maximum steady-state output power is limited to a total of 1140 W
for any combination of output voltages/currents at low-line 100-120 VAC
nominal input voltage conditions.
The maximum steady-state output power is limited to a total of 690 W
for any combination of output voltages/currents, excluding the 50 VDC
source at low-line 100-120VAC nominal input voltage conditions. This
limitation is required to ensure that there is sufficient PoE power or 450
W total at this input voltage condition.
The maximum steady-state output power is limited to a total of 870W
for any combination of output voltages/currents, excluding the 50 VDC
source at high-line 200-240VAC nominal input voltage conditions. This
limitation is required to ensure maximum PoE power or 900 W total for
the 50 VDC source at this input voltage condition.
To obtain the full output power rating of 1770 W, you must connect the
power supply to a nominal (200-240VAC) input voltage source.
The following table list the power specifications for the Ethernet Routing
Switch 8302AC power supply.
Table 6
Ethernet Routing Switch 8302AC power specifications
AC Input Power Ratings
Input voltage range (nominal):
100-120 VAC
200-240 VAC
Input current (nominal):
12 A
9 A
Frequency range (nominal):
50-60 Hz
50-60 Hz
Input VA
1192 VA
1768 VA
Input power consumption:
1180 W
1750 W
Heat dissipation
(thermal/output):
1126BTU/hr
1195 BTU/hr
Hold-up time:
20 ms
20 ms
DC Output Power Ratings
Max. output power (combined):
850W (760W + 90W fans)
1400 W (1310W + 90W fans)
Non-PoE:
3.3 VDC @ 150 A
3.3 VDC @ 150 A
12 VDC @ 65 A
12 VDC @ 65 A
PoE:
50 VDC @ 18 A
50 VDC @ 18 A
Fans:
12 VDC @ 7.5 A
12 VDC @ 7.5 A
Nortel Ethernet Routing Switch 8300
Installation — AC Power Supply
NN46200-301
03.01
Standard
4.0
27 August 2007