Nortel Networks 13.03 User Manual

Page of 24
BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes
1-4
305279-C Rev 00
CR 82539: PPP
The router fails to establish a Point-to-Point Protocol (PPP) session with the RAD/
WebRanger routers. This problem occurs when remote users attempt to access the 
central site.
CR 83167: OSPF
A fault occurs in IP when the route table manager fails to delete an entry from the 
routing net pool. This condition occurs when a network interface in a 
non-backbone area goes down after having learned an OSPF route that is in the 
summary range defined in the backbone area.
CR 85093: IP
When running BaySecure Firewall on an ARN router, the free buffer list becomes 
corrupt, causing a bus error when allocating a buffer. 
CR 87645: 100BT
Lancast 100bt transceiver fails operating system diagnostics.
CR 88632: Boot Prom
The ARN router experiences intermittent boot failures when it incorrectly enters 
into diagnostic mode. ARN boot proms require upgrade to version 1.27.
CR 90108: IPX
RCONSOLE and some Lotus Notes applications do not work when IPX traffic 
goes over a DOD hot standby circuit.
CR 90436: ATM
When a PVC is configured with an illegal VCI number, it remains in an init state 
and cannot be deleted using the BCC. You can only delete the PVC through the 
MIB set. 
CR 91128: ATM
Toggling a PVC while it is in an init state causes a fault. The init state occurs when 
two PVCs are using the same service class value within the same PVC group.