Sterling Plumbing Musical Table 882.00252.00 User Manual

Page of 52
3–Pump 33-Station Controllers 
Chapter 3:  Installation 
14 of 51 
Connecting the Control Panel to Vacuum Hoppers 
Note: 
Wire size depends on control voltage, distance, number of vacuum 
hoppers, and the number of wires in each raceway. Consult a qualified 
electrician. 
1.  On 115 VAC control voltage systems, run a common hot (115 VAC) wire and 
a common neutral wire from the controller to each vacuum hopper in the 
system.   
On 24 VDC control voltage systems, run a common +24 VDC wire and a 
common 0 (zero) VDC wire from the controller to each vacuum hopper in the 
system. 
2.  On all systems, run two wires to each vacuum hopper:  one each from the 
controller to the Bin-Full switch (LS) and to the Atmospheric/Sequence-T 
solenoid (SOL) valve. 
3.  Make sure that the solenoid and the proximity switch (if supplied) on vacuum 
hoppers are the same voltage (24 VDC) as the control panel voltage. Consult 
the control panel serial tag and the solenoid valve nameplates. 
4.  Wire size depends on control voltage, distance, number of vacuum hoppers, 
and the number of wires in each raceway.  Consult a qualified electrician. 
5.  Properly ground each hopper to reduce static build up generated by material 
conveying.  
Connecting the Control Panel to the Pump Package 
1.  Wire the pump package motor starter coil (M) to the terminal provided in the 
control panel enclosure. 
2.  Wire the pump package vacuum relief valve solenoid (SOL A) to the terminal 
provided in the control panel enclosure. 
3.  Wire the pump package vacuum switch (VS) to the terminal located in the  
control panel enclosure. 
4.  On vacuum pumps, wire the pump package blowback solenoid (SOL B) to the 
terminal located in the control panel enclosure. 
5.  On 115 VAC control voltage systems, run a common hot (115 VAC) wire and 
a common neutral wire from the controller to each pump package in the 
system. 
On 24 VDC control voltage systems, run a common +24 VDC wire and a 
common 0 (zero) VDC wire from the controller to each pump package in the 
system.