Sterling Plumbing Musical Table 882.00252.00 User Manual

Page of 52
3–Pump 33-Station Controllers 
Chapter 4:  Operation 
29 of 51 
4.  When you are finished reviewing the information, touch Return. The “Help Menu” 
screen opens.  
5.  Touch Menu to return to the “Menu” screen. 
The following table explains the status represented by each color at the “Station Status” 
screen. 
Color Label 
Description 
Gray outline 
Offline 
Station is not enabled. The controller ignores any demands or 
alarms. 
Blue 
Ready 
Station is enabled and idle (full). 
Yellow 
Demand 
Station requires material. 
Green 
Loading 
Station is being loaded with material. 
Light blue 
Dumping 
Station is dumping material into its receiver. 
Green, blinking 
Priority 
Station is in priority convey mode. Its pump will be temporarily 
dedicated to filling it as soon as possible. 
Red, blinking 
Alarm 
Station is in alarm. 
Red outline, blinking 
Critical 
Station is in critical alarm. The controller has disabled the station 
until the alarm is cleared. 
 
Additional basic information about each station (convey time, dump delay, and pump 
assignment) is available at the “Station Operator” screen. See page 33 for details. 
Detailed configuration settings for each station are available at the “Station Setup” screen. 
See page 42 for details about each of these settings.