3–Pump 33-Station Controllers 
Chapter 4:  Operation 
38 of 51 
9.  Enter the number of the standby pump. Use 
 (Backspace Key)  to erase any 
mistakes. Use 
 (Enter Key) to enter the value. The number appears under 
Standby Pump, and a button labeled Transfer to Standby Pump appears on the 
screen. 
Figure 17:  Transfer To Standby Pump Button 
 
Note: 
When you enter the second pump number, the controller checks to make sure that 
both pumps are offline and that the standby pump has no stations assigned to it. 
If these conditions are not all met, error messages appear on the screen instead 
of a Transfer to Standby Pump button. If you get an error message, first 
check to make sure that you have entered the correct numbers and reenter if 
necessary. If another error occurs, see the Standby Pump Errors section on page 
38. 
10. Touch Transfer To Standby Pump. “Transfer in Progress” appears briefly on the 
screen, followed by “Transfer Complete,” in place of the Transfer To Standby 
Pump
 button. The controller switches the setting for Source Pump to the new 
pump and switches the setting for Standby Pump to 0 (unassigned).  
11. Touch Return, and then Pumps to return to the “Pump Status” screen. 
12.  Put the standby pump online by briefly touching its icon. The icon changes color to 
show the new status, and the system begins using the pump. In addition, all “Station 
Operator” and “Station Setup” screens show the new pump assignment.  
When the failed pump is operational again, you can repeat this process, this time using the 
standby pump’s number as the setting for Source Pump the repaired pump’s number as the 
setting for Standby Pump