3–Pump 33-Station Controllers 
Chapter 6:  Configurable Settings 
44 of 51 
6-2  Options for Pump Setup 
Several of the items in this screen are not setup options but are instead intended for use 
during operation. These items (hour meter and transferring stations to a standby pump) are 
described in Chapter 4, which cover operation procedures. 
Name Description 
Options 
Default 
Idle Time Options 
Auto shutdown delay 
Length of time the pump continues to run unloaded 
without demand from any station. After this time has 
elapsed, the pump shuts down to save power and to 
prevent wear on the pump. 
Adjust this setting to fit the needs of your facility 
in trading off the savings against the costs 
associated with waiting for a pump to start up 
when there is a demand for material. 
0–999 sec. 
45 sec. 
Alarm Options 
Pump fault  
The control has one input/pump that you can wire to 
generate alarms for situations of your choosing. For 
example, you may have a sensor that turns on when 
material reaches the top of a filter-chamber waste 
bin. When this option is enabled, the controller issues 
an alarm if the sensor wired to the input for Pump 
Fault turns on. 
Enable this option if and only if your facility has 
installed a miscellaneous alarm on the input for 
Pump Fault for this pump. 
disabled, 
enabled 
disabled 
Blow Back Options 
Blow back 
When this option is enabled, the controller 
periodically sends compressed air backward through 
the pump’s air filter to dislodge accumulated dust and 
debris. 
Enable this option if and only if the pump has the 
equipment for compressed-air filter cleaning. 
disabled, 
vacuum pulse 
enabled 
comp air 
enabled 
disabled 
Every loads 
Number of conveying cycles to stations between filter 
cleanings. 
Adjust this setting based on experience. The more 
dust and debris in your material line, the smaller this 
number needs to be. 
1–99 5 
# pulses 
Number of pulses of compressed air sent through the 
pump’s filter during cleaning. 
If filter-cleaning is not working as desired, the service 
department may ask you to change this setting. 
1–99 5 
On time 
 
Number of seconds that the air compressor remains 
on for each pulse during filter cleaning. 
If filter-cleaning is not working as desired, the service 
department may ask you to change this setting. 
0.1–99.0 sec. 
1.0 sec. 
Off time 
 
Number of seconds between air pulses during filter 
cleaning. 
If blow-back is not working as desired, the service 
department may ask you to change this setting. 
0.5–99.0 sec. 
1.0 sec.