Sterling Air Compressor SSV-05R User Manual

Page of 37
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 
14 of 36 
 
2-4  Connecting the Compressed Air Supply 
Before connecting the compressed air supply, check the following: 
  Check compressed air piping for correct installation and assembly. 
  Check the fittings, length and quality of the hose connections for 
agreement with requirements. 
  Check all compressed air lines for leakages. 
You need a compressed air supply with 70-90 psi (5-6 bar) system pressure.  
The air should be free of oil and water.
       
 
1.  Find the compressed air hose, which has 
been supplied.   
2.  Connect it to the venturi assembly and to 
the control and maintenance unit.  
3.  The compressed-air hose is firmly pressed 
into each connecting socket. 
4.  Connect the control and maintenance unit 
to the compressed air supply.  Max. input 
pressure 145 psi (10 bar) system pressure. 
5. 
Set the pressure on the pressure reducer 
at 70-90 psi (5-6 bar).
 
        
 
 
 
 
Maximum input pressure: 145 psi (10 bar) system 
overpressure. 
 
Maximum output pressure: 90 psi (6 bar).
 
Figure 3:  Venturi Assembly