Sterling Air Compressor SSV-05R User Manual

Page of 37
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 
19 of 36 
 
4-3   Basic Setting of the Filling Level in the Conveyor Hopper 
The filling level in the conveyor hopper is mainly determined by the level sensor. 
 
 
 
Figure 6:  Conveyor Hopper
 
 
 
 
 
 
 
 
 
 
 
 
Filling Level Too Low 
1.  Using a screwdriver, turn the adjustment screw of the level sensor (A) ¼ 
rotation counter-clockwise. 
2.  Check the filling level during the next conveying procedure. 
3.  Repeat the process until the desired filling level in the conveyor hopper is 
reached. 
Filling Level Too High 
1.  Using a screwdriver, turn the adjustment screw (A) of the level sensor ¼ 
rotation clockwise. 
2.  Check the filling level during the next conveying procedure. 
3.  Repeat the process until the desired filling level in the conveyor hopper is 
reached.