Factory Initialization
Factory Initialization
Factory initialization is a process that all new IP4700 systems 
experience prior to shipment. The process begins by clearing all data 
from the DPE and DAE(s) in the IP4700 system, and then binds the 
disks into file server volumes. You must follow this same process to 
complete the FC4700-to-IP4700 conversion, and leave your system 
ready for the network initialization process common to all IP4700 file 
servers. 
1. Locate the DPE serial number label on the back of the unit. Copy 
the number here – __________________________. 
You will need it later in the procedure. 
2. Verify that the yellow SPS LEDs are off and the green LEDs are 
either on or flashing.
3. power cycle the DPE as described in Chapter 2 of the IP4700 
Installation and Service Guide:
a. Turn the power switches on the Standby Power Supplies to the 
off position. 
b. Wait for all LED activity on the DPE to cease, and for the fans 
to stop running. (Note that if the SPS was in the ready state it 
will hold power for 90 seconds.)
c. Wait an additional 30 seconds.
d. Turn on the power switch on SPS A, then do the same for SPS 
B.
4. Enter ^V (CTRL-V) immediately when the system displays the 
IP4700 banner.