Jasco 24772 Instruction Manual

Page of 1
WARNING
!
Risk of electric shock
- Do not use in wet locations.
- Use indoors only.
- Turn power off before servicing -
  see instructions.
- Properly ground fixture.
- Ensure that no bare wires are exposed
  outside the electrical connections.
- Use within electrical rating of device
**This device is intended for use only with 
  GE Linkable products. Use of any other 
  lighting product may be hazardous.
INSTALLATION PROCEDURES
FOR ELECTRICAL BOX
1) Consult a local licensed electrician or
  electrical contractor if you are not sure
  about the installation.
2) Ensure that electricity is TURNED OFF at the
  main circuit breaker or fuse box. DO NOT
  ATTEMPT TO INSTALL ELECTRICAL BOX
  WITH THE POWER ON.
3) Select a suitable dry mounting location
  (for use indoors only). Make sure the
  mounting surface is capable of supporting
  the fixture.
4) Remove plastic cover from electrical
  mounting box by unscrewing the 2 screws.
5) Choose a suitable knock-out location from
  those provided on the box. Remove the
  knock-out with a screw driver. See Figure 1.
6) Place the electrical box in the location where
  it is to be mounted and mark the position of
  the mounting slots with a pencil.
7) It is recommended that a 1/16" pilot hole be
  drilled in the mounting surface.
8) Drive the screws provided in the mounting
  hardware into the mounting surface until the
  electrical box is secure.
9) Insert the threaded end of the strain relief
  (provided in the installation kit) into the selected
  knock out opening on the electrical box. Place
  the eyelet of the grounding (copper) wire provided
  in the installation kit around the strain relief. The
  grounding (copper) wire & eyelet should be
  located inside of the box. Secure the strain
  relief by tightening the lock nut. See Figure 1.
10) Install the conduit or armored cable to meet
  electrical codes. Tighten the two screws on
  the strain relief connector to secure the wires.
11) Connect the hot (black) AC supply wire(s) to
  the hot (black) wire in the electrical box.
  Secure the connection with the wire nuts
  provided. See Figure 1.
12) Connect the white (neutral) AC supply wire(s)
  to the neutral (white) wire in the electrical box.
  Secure the connection with the wire nuts
  provided. See Figure 1.
13) Connect the ground (green or copper) AC
  supply wire to the copper ground wire of the
  electrical box. Secure the connection with
  the wire nuts provided. If your electrical
  system contains no grounding wire, you
  should consult a qualified electrician before
  proceeding with the installation. See Figure 1.
14) Ensure that no bare wires are exposed after
  making the electrical connections.
15) Arrange the wires inside the fixture and
  reattach the plastic cover of the electrical
  box. Tighten the screws to ensure that all
  the wires and connections are sealed
  properly inside the fixture without "pinching"
  any wires.
Figure 1
Quick Connect
AC Supply
Wires
Hot (Black)
Supply Wire
Hot (Black)
Box Wire
Ground
(Green or
Copper)
Wires
Neutral (White)
Supply Wire
Neutral (White)
Box Wire
Strain
Relief
Knock
Out
UCF012-front
24772-2 rev11/18/05