Casio Personal Computer CTK-900 User Manual

Page of 80
58
Part VI
Parameter Set List 
This list shows the parameter sets that can be transferred using System Exclusive Message Bulk Dump. 
26
User Tone Parameter Set 
System Exclusive Format
27
User Timbre Parameter Set 
This is the parameter set that is associated with and sent with  Tone.  
System Exclusive Format
Field
Value 
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
04
dev
Either 00 to 1F, or 7F
05
act
04(HDS), 05(HDR), 07(Control)
06
cat
Tone = 02
07
prm
00-7F 
08
ilen/dlen See "IV This Model's System Exclusive Messages".
09
ps
Indicates the tone number being transferred. 
For details, see "39 About Parameter Set (PS) numbers". 
10
index
See "IV This Model's System Exclusive Messages".
11
data
See "IV This Model's System Exclusive Messages".
12
sum
See "IV This Model's System Exclusive Messages".
13
EOX
F7 
Field
Value
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
04
dev
Either 00 to 1F, or 7F
05
act
04(HDS), 05(HDR), 07(Control)
06
cat
Timbre = 03
07
prm
00-7F 
08
ilen/dlen See "IV This Model's System Exclusive Messages".
09
ps
Indicates the timbre number being transferred.
For details, see "39 About Parameter Set (PS) numbers".
10
index
See "IV This Model's System Exclusive Messages".
11
data
See "IV This Model's System Exclusive Messages".
12
sum
See "IV This Model's System Exclusive Messages".
13
EOX
F7