Cable and Waveguide Connections 
 
Cabling Requirements 
Local regulations may require that cables in occupied buildings be installed in steel conduit. Local 
government agencies may waive this requirement for the use of Plenum cables, which are standard 
cables entirely encased in solid Teflon. Check the codes in your area. 
NOTE: E
QUIPMENT OUTAGES DUE TO FAULTY CABLE MATERIALS OR INSTALLATION ARE NOT 
COVERED BY YOUR WARRANTY
.  
 
AC Power 
 
Attach the AC input cable to the 4-pin connector on the SSPA, shown in Figure 4. Run the AC 
cable to the power source but do not attach. The supplied power cable has a four-pin weather-
tight circular connector attached to one end. The other end is terminated with flying leads. Attach 
the proper AC power connector for your location to the other end of this cable as shown in Figure 
5 below. 
 Color 
code: 
Brown..................AC Hot power lead 
Blue......................AC Neutral power lead 
Green/Yellow......Ground 
 
Figure 4  - AC Power Connection 