Avery ALS 206 User Manual

Page of 58
50
C
ONTENTS
6.1 E
RROR
 
MESSAGES
ALS
20x 
256
GB
6.1.1
Reporting errors
When an error occurs, the machine stops immediately 
and displays an error message on the control panel.
Error messages are displayed as follows:
[52] An example of an error message:
5144 = status number; this number makes it easier to identify the 
message.
‘Rewinder init’ = status text; a brief description of the error.
Error messages that are not described here may only 
be resolved by a qualified service technician.
When an error occurs that is not described here:
£
Press the button 
 to delete the message.
£
Switch the device off, wait 30 seconds and then 
switch it on again.
If the error reoccurs:
£
Request a service technician.
Error messages that are not mentioned here 
are described in the service manual.
6.1.2
List of error messages
Status num:
5144
Rewinder init20x 256
Status
Status text
Cause
Action to take
5000
Bus device
– Device at I
2
C Bus cannot be contact-
ed. 
– In most cases, this message appears 
as the first in a series of two or three 
messages which narrow down the er-
ror more precisely.
£
Delete the message by pressing the 
 -key.
£
Switch the machine off, wait 30 sec-
onds and switch it back on.
£
If the error message 
appears re-
peatedly, call in a servicing tech-
nician.
5001
No gap found
– The maximum limit for missing labels 
was exceeded (
LABEL SETUP > Miss. la-
bel tol.
).
– The machine is not correctly set for 
the type of label (
MACHINE SETUP > 
Light sens. type 
).
– Label length is not correctly set 
(
LABEL SETUP > Label distance
).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is incor-
rectly positioned.
– Photoelectric label sensor is not con-
nected correctly.
– Photoelectric label sensor is defec-
tive.
– Rotary encoder is not adjusted cor-
rectly.
£
Check the points listed above and 
correct if necessary.
£
Press the 
 key to confirm the er-
ror message.
5002
Rewinder full
The (internal) roll diameter control has 
calculated that the end of the material 
roll has been reached.
£
Insert new label roll.
[53]
List of error messages
6
O
P E R A T I O N A L
 
F A I L U R E S
6.1
ERROR MESSAGES